Diesel Generator Set

Diesel Generator Sets Manufacturer

Our diesel generator sets are grouped into different power ranges to match your specific applications. From small backup power for shops and offices to large industrial diesel generators for heavy-duty continuous operation, we have the right model for your project.

As a professional diesel generator set manufacturer,Dingbo sells diesel generators from 20 kW to 3,000 kW in all brands to meet different performance and budget requirements such as Cummins, Volvo, Perkins, Yuchai, Doosan, Shangchai, Ricardo, Weichai, MTU and other brands.

For detailed models and specifications, please browse the sub-categories or contact our engineering team for a tailored diesel generator set proposa.


Diesel Generator Brands, Power Ranges and Available Models

Explore diesel generator sets by engine brand and power range. View available models below, or send us your required output to compare suitable configurations and prices.

Engine BrandPublished Series RangeSelected Product Outputs, kW / kVA
Cummins25–1875 kVA80/100, 200/250, 400/500, 600/750, 800/1000, 1200/1500, 1500/1875
Perkins25–2475 kVA30/37.5, 120/150, 180/225, 280/350, 300/375, 640/800, 1000/1250
Volvo85–770 kVA160/200, 250/312.5, 300/375, 350/437.5, 500/625, 560/700
Yuchai25–2750 kVA60/75, 100/125, 140/175, 400/500, 450/562.5, 500/625, 1200/1500
Weichai25–2750 kVA30/37.5, 90/112.5, 160/200, 200/250, 260/325, 320/400
Shangchai / SDEC56–2250 kVA50/62.5, 220/275, 330/412.5, 350/437.5, 750/937.5, 800/1000
Deutz25–750 kVA25/31.25, 80/100, 160/200, 250/312.5, 320/400, 350/437.5, 400/500
MTU250–3125 kVA200/250, 320/400, 516/645, 728/910, 800/1000, 1300/1625, 2200/2750
Doosan50–2750 kVA120/150, 160/200, 304/380, 420/525, 540/675
Licaduo25–2750 kVA24/30, 160/200, 550/687.5, 650/812.5, 850/1062.5, 1000/1250, 1500/1875

Series ranges do not mean that every intermediate output is available. Send your required capacity if it is not shown.


Explore Diesel Generator Sets at Your Required Output

Start with these product groups to find specific models. Where several brands offer the same listed output, compare their operating ratings and configurations before treating them as equivalent alternatives.


How to Choose a Diesel Generator Set

After finding the required power range in the table above, the next step is to define the electrical output, generator components and control requirements. These details allow us to match a specific diesel generator set instead of quoting only by kVA.

1. Confirm the Exact Electrical Specification

Start with the electrical specification that the generator must supply.

Required InformationWhat to Provide
OutputRequired kW or kVA
Duty ratingPrime power or standby power
Frequency50 Hz or 60 Hz
VoltageFor example, 380/220 V, 400/230 V, 415/240 V or your project voltage
PhaseSingle phase or three phase
LoadMain equipment powered by the generator and the largest starting load

If you are replacing an existing diesel generator set, send us a photo of the existing genset nameplate. We can use its rated power, voltage, frequency and operating rating as the starting point for model selection.

2. Specify the Engine, Alternator and Controller Combination

After the required output is confirmed, use the brand and power range table above to shortlist the available engine series.

The next comparison should be based on the complete generator set configuration, not the engine brand alone.

Engine

Choose from the engine series available within your required output range, including:

If no engine brand is specified in your tender or project, send us the required output and budget level so that we can provide available combinations for comparison.

Alternator

Dingbo diesel generator sets can be configured with different alternator brands according to the model and project specification, including:

If your tender specifies the alternator brand, IP protection, insulation class or AVR requirement, include it in the RFQ.

    The controller should be selected according to what the diesel generator set must actually do: local operation, automatic mains-failure operation, remote monitoring or multi-generator synchronization.

    3. Tell Us How the Generator Must Start and Connect to the Power System

    The control scope should be defined before the quotation because a basic single generator, an automatic standby system and a parallel generator system require different equipment.

    Required OperationConfiguration to Discuss
    Manual/local generator operationSingle diesel generator set with standard control panel
    Automatic start after mains failureAutomatic-start/AMF control configuration
    Automatic transfer between mains and generatorGenerator + Automatic Transfer Switch
    Two or more generators operating togetherGenerator sets + Synchronous Parallel System
    Remote operating-data accessCompatible controller + Dingbo remote monitoring solution

    4. Choose the Installation Type

    InstallationConfiguration to Consider
    Dedicated generator room with suitable ventilation and exhaust provisionsOpen-type diesel generator set
    Outdoor installation with a specified sound limitSilent Diesel Generator Set
    Larger enclosed equipment packageContainerized Diesel Generator
    Equipment moving between work locationsTrailer-Mounted Diesel Generator

    For silent models, compare sound levels at the same measurement distance and operating load. For enclosed equipment, include cooling airflow and maintenance access when checking the required installation space.


    Applications

    Dingbo’s diesel generator sets are designed to provide reliable power in diverse environments. Below are some typical applications:

    Factories and Industrial Plants: Continuous power for production lines, machining workshops, and process equipment.

    Hospitals and Healthcare Centers: Stable backup power generators for critical medical equipment and operating theaters.

    Data Centers and IT Facilities: High-reliability industrial diesel generators with fast response and parallel capability.

    Construction Sites: Mobile or trailer-mounted diesel generators for temporary power, compatible with heavy equipment and tools.

    Mining and Remote Operations: Robust diesel generator sets for harsh environments and continuous heavy-duty loads.

    Commercial Buildings: Standby power solutions to ensure business continuity during grid outages.

    If you are looking for a diesel generator, our engineers can propose the most suitable configuration based on your load profile and local conditions.


    Request a Quote for Your Diesel Generator Set

    Tell us your power requirements, site conditions, and preferred engine brand, and our engineering team will provide a tailored proposal.Contact us quickly.


    Follow Us

    WeChat

    WeChat

    Contact Us

    Mob.: +86 134 8102 4441

    Tel.: +86 771 5805 269

    Fax: +86 771 5805 259

    E-mail: dingbo@dieselgeneratortech.com

    WhatsApp: +86 134 8102 4441

    Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China

    Get in Touch

    Enter your email and receive the latest news from us.

    Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap Update cookies preferences | privacy-policy
    Contact Us