Dingbo Power Exported A 80Kva Cummins Diesel Genset to Tanzania

Feb. 18, 2025

In December, 2024, Dingbo Power exported a prime power 80kva silent type diesel generator set to Tanzania. The genset is powered by DCEC Cummins 4BTA3.9-G11 diesel engine, which has a prime power of 70KW/88kva and a standby power of 80KW/100kva at 1500 rpm. The power generator can provide high performance, high efficiency and low emissions.


Technical data of 80kva diesel generator


Manufacturer: Guangxi Dingbo Generator Set Manufacturing Co.,Ltd.

Genset model: DB-64GF

Type: Silent type

Prime power: 64kw/80kva

Standby power: 72kw/90kva

Rated voltage: 400/230V

Rated Current: 115A

Speed/frequency: 1500rpm/50Hz

Power factor: 0.8lag

Phase & Wire:3 Phase 4 Wire

Diesel engine: Cummins 4BTA3.9-G11

Alternator: Shanghai Stamford GR225G

Controller: SmartGen HGM7220N


Main engine specifications


Manufacturer: Dongfeng Cummins Engine Co.,Ltd

Model: 4BTA3.9-G11

Engine output-prime/standby: 70kW/80kW

Frequency: 50Hz

Speed: 1500rpm

Cylinder number: 4

Cooling method: Water-cooled

Aspiration: Turbocharged & Aftercooled

Bore*stroke: 102*120mm

Displacement: 3.9L

Compression Ratio: 17.3:1

Governor: Electronic speed governor

Starter motor voltage: 24V DC

Type Injection System: BYC PB direct injection

Coolant Capacity - Engine Only: 8.3L

Minimum Required Lube System Capacity - Sump plus Filters: 10.9L


This genset is equipped with a soundproof enclosure, which is made of 2mm galvanized sheet. The generator enclosure is weather-proof, dust-proof and non-corrosive. It can protect the generating set from inclement weather and other adverse environmental factors, and keep the components of diesel generator free of debris and moisture. This makes it possible to install a silent type generator set anywhere. In addition to weather protection, the generator canopy also provides sound reduction and safety functions.


Dingbo Power Exported A 80Kva Cummins Diesel Genset to Tanzania


Soundproof diesel generator sets are widely used in applications where silent operation is required: hospitals, health centers, hotels, office buildings, etc. They are also increasingly used at outdoor events where electricity is required, without disturbing the attendees.


The 80kva diesel generator is has a built-in 125A automatic transfer switch (ATS), which can  switch the diesel generator on when there is a loss of power, and once the regular power supply comes back, it turns off. This device automatically transfers a power supply from its primary source to a backup source when it senses a failure or outage in the primary source. Following the failure, the ATS automatically invokes the backup source to minimize power supply disruptions.


How to operate a diesel generator?


After buying a new diesel generator, please read the user manual and follow the instructions and recommendations of manufacturer to operate your generator. Generally, to operate a diesel-powered generator set safely and efficiently, you can follow the key steps below.


Pre-operation checks


Before starting your diesel generator, visual inspections are necessary. Check for loose parts, damaged wiring, or leaks. Ensure the battery is charged and terminals are clean and tight. Check the fuel level, oil level and coolant level. Make sure they are at the correct levels. Ensure all electrical loads are off before starting.


Starting the generator


Start the diesel generator and allow the generator to run at no load for 3~5 minutes to stabilize oil pressure and temperature. In cold conditions, you may need to preheat the engine by activating the glow plug or other preheat functions if equipped.


Connecting loads


Connect essential loads one at a time and watch the voltage, frequency, oil pressure, and coolant temperature during operation.


During operation


During the generator operation, check fuel, oil, and coolant levels periodically and check if there are any unusual noises or vibrations. Avoid overloading the diesel generator to prevent damage.


Shutdown procedure


To shut down the diesel generator, you need to disconnect loads and let the generator run at no load for 3~5 minutes to stabilize internal temperatures. Then turn off the generator. You can use the emergency stop button if abnormal noises, smoke, or critical failures occur.


Keep in mind that generators produce exhaust gases like carbon monoxide, which is colorless, odorless, and potentially deadly. Remember to place it outdoors at least 20 feet from your home's doors, windows, or vents. Or place it in a dedicated generator room with well ventilation.


If you are looking for a diesel generator set, feel free to contact Dingbo Power today.


Follow Us

WeChat

WeChat

Contact Us

Mob.: +86 134 8102 4441

Tel.: +86 771 5805 269

Fax: +86 771 5805 259

E-mail: dingbo@dieselgeneratortech.com

WhatsApp: +86 134 8102 4441

Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China

Get in Touch

Enter your email and receive the latest news from us.

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap Update cookies preferences | privacy-policy
Contact Us