Dingbo Power Exported A Prime Power 100KW Cummins Diesel Genset to Cameroon

Sep. 28, 2024

In May, 2024, Dingbo Power produced and exported a prime power125KVA Cummins silent diesel generator set to Cameroon. The genset is powered by a Cummins 6BTA5.9-G2 engine and coupled with an original Stamford UCI274ES14 alternator and a SmartGen HGM6110N controller.


Technical data of 100KW 125KVA diesel generator set


Manufacturer: Guangxi Dingbo Generator Set Manufacturing Co.,Ltd.

Genset model: DB-100GF

Type: Silent type

Prime/standby power rating: 100kw/110kw

Rated voltage: 400

Rated Current: 180A

Speed/frequency: 1500rpm/50Hz

Phase & Wire: 3 Phase 4 Wire

Power factor: 0.8lag

Diesel engine: Cummins 6BTA5.9-G2

Alternator: original Stamford UCI274ES14

Controller: SmartGen HGM6110N


This 100kW diesel generator set comes with an offwhite soundproof enclosure and a 8-hour base bottom fuel tank. The noise level of this silent diesel generator is 75dB(A) at 7 meters. It is drived by water cooling Cummins diesel engine model 6BTA5.9-G2.


Dingbo Power Exported A Prime Power 100KW Cummins Diesel Genset to Cameroon


Below are the specifications of the engine:


ManufacturerDongfeng Cummins Engine Co.,Ltd
Model6BTA5.9-G2
Engine output-prime106kW
Engine output-standby116kW
Frequency:50Hz
Speed:1500rpm
Cylinders no. & Type:6 cylinders, Inline, 4 stroke, diesel engine, water-cooled
Aspiration:Turbocharged & Aftercooled
Bore*stroke102*120mm
Displacement5.9L
Compression Ratio17.3:1
GovernorElectronic speed governor
Starter motor voltage:24V DC
Type Injection System:direct injection
Maximum Oil Temperature121℃
Minimum Required Lube System Capacity - Sump plus Filters16.4L
Cooling wayWater Radiator & fan
Coolant Capacity - Engine Only10L
Standard Thermostat82-95℃
Fuel consumption-standby power (100%)30L/h
Fuel consumption-prime power (100%)27L/h
Fuel consumption-prime power (75%)20L/h
Fuel consumption-prime power (50%)14L/h
Fuel consumption-prime power (25%)8L/h

 

This 100KW Cummins silent diesel generator can provide a consistent and uninterrupted power supply during blackouts or when off-grid power is needed. It produces electricity without noise, making it perfect for use in homes, hospitals, industries, and other noise-sensitive locations.


How to keep your diesel generator running smoothly?


Like other machinery, diesel generators also need to be regularly maintained to ensure it works properly and smoothly. If you own a diesel generator but neglect the regular generator maintenance, it can shut down and stop working when needed. To avoid generator breakdowns and the need for costly repairs, you can follow the tips below to take care of your diesel generator.


Routine inspections


It’s necessary to perform regular visual inspections of your diesel generator. Check the exhaust system, fuel system, DC electrical system and the engine periodically for any signs of leaks, loose connections, corrosion or other kinds of malfunctioning. If any issues are found, fix them timely to prevent major problems in the future.


Fuel system checks


Diesel fuel has a limited shelf life and it is prone to contamination and corrosion over time. Therefore, it’s suggested that you run the generator every now and take some measures, such as draining fuel filters at proper intervals and regular fuel testing and polishing, to prevent contamination and ensure that the fuel remains in the best form. You should also check the fuel lines, filters, injectors, starting system and charge-air cooler piping and hoses regularly and replace fuel filters as recommended by the manufacturer.


Cooling system checks


Inspect the radiator, coolant levels, and hoses regularly during the shutdown period. Check the radiator for obstructions and use a soft brush to remove all dirt and foreign materials. Ensure that the coolant level is within the recommended range, and top it up with the appropriate coolant mixture if necessary. Replace the coolant according to the manufacturer’s recommendations.


Battery maintenance


Weak or dead batteries is a common cause of standby power system failures. You should regularly test the batteries in your generator and ensure that they are in good condition. The batteries should also be cleaned periodically to prevent corrosion. If corrosion is found on the terminals, you should remove the cables and clean them with a solution of baking soda and water. Ensure that the battery is securely fastened and the connections are tight.


Routine engine excising


Regular engine exercising is essential because it can keep the engine lubricated optimally and prevent oxidation of electrical contacts. By doing this, you can use the fuel before it deteriorates. A minimum of 30 minutes exercise once a month is recommended to ensure that the engine remains up and running.


Looking for a diesel generator for your home or business? Don’t hesitate to reach out for any further information or assistance regarding to diesel generators. Contact Dingbo Power today!


Follow Us

WeChat

WeChat

Contact Us

Mob.: +86 134 8102 4441

Tel.: +86 771 5805 269

Fax: +86 771 5805 259

E-mail: dingbo@dieselgeneratortech.com

WhatsApp: +86 134 8102 4441

Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China