dingbo@dieselgeneratortech.com
+86 134 8102 4441
Diesel Generator Set Data
Model: DB-140GF
Prime power: 140KW/175KVA
Rated current: 252A
Rated frequency: 50Hz
Power factor: 0.8lag
Rated voltage: 230/400V
Start Mode: Electric start
Engine: Yuchai YC6A230-D30
Alternator: STAMFORD/SIEMENS/MARATHON/ENGGA /LEROY SOMER
Quality: ISO-certified and CE-certified.
For more types, please contact us.
140kW 175 kVA Yuchai YC6A230-D30 Engine Diesel Generator Sets
Dingbo DB-140GF is a 140kW & 175 kVA Three Phase 50Hz Diesel Generator powered by Yuchai YC6A230-D30 engine, which characterized by high cost performance, easy use and maintenance, and superior NVH performance.
Why Choose Us
Dingbo is original manufacturer of diesel generator set. Factory direct sale, guaranteed quality and affordable price.
Our diesel generator sets are widely used in telecommunications, energy, transportation, real estate, hospital, residential building, data center and other fields, having long-term strategic cooperation with a lot of well-known enterprises. From research and development to production, from raw material procurement, assembly and processing to finished product debugging and testing, each process is strictly implemented, in all aspects meet the national, industry standards and contract provisions of the quality, specifications and performance requirements.
We have a professional and technical team, with an average working experience of more than 10 years in the generator industry. In the spirit of "keep improving", they actively collect and attract advanced technology and products at home and abroad, and constantly update the products, so that our diesel generators have been recognized by the majority of users.
If a customer can not find his supplier to support them when equipment has problem, after sales service is not guaranteed, which is a very helpless thing. While we have perfect after-sales service to support you to solve problem, it's not that you can't find us after you have a problem on your equipment. We will be with you and solve your problems with heart.
Export Case
So far, our diesel genset sold to Ethiopia, Venezuela, Singapore, Nigeria, Thailand, U.S.A etc. all over the world, both having good feedback from customers.

Specific Project Cases:
FAQ
1. Do you have your own factory?
Yes, we have. Welcome to visit our factory.
2. What is the delivery time and do you have product in stock?
Delivery time depends on order quantity. Generally, within 10 days for open genset, 20 days for silent genset. We have some power capacities in stock, if need details, please contact us.
3. What is your warranty period?
Our warranty is 1 year or 1000running hours whichever comes first. But based on some special project, we can extended our warranty period.
4. Does your generator have global warranty?
Yes, We supply the warranty. Also most of our products like Cummins, Volvo, Perkins, Deutz, Doosan, Yuchai, Weichai etc. power generator enjoy the global warranty service. And the alternator we use like Stamford and marathon also enjoy the global warranty service, so you do not need to worry about the after-sales service.
5. What is your payment terms?
We can accept T/T 30% in advance, and the balance 70% shall be paid before shipment or L/C at sight. But based on some special project and special order, we can do something on payment item.
6. Do you provide OEM service?
Yes, we can put your company logo on our diesel genset, just tell us your requirements, then we will do it for you.
Our Service
Before service
Our professional engineer will give you some consultation of technology and related planning before sale, such as selection of equipment, supporting facilities, the design of equipment room. We can also answer and solve the using problem you faced.
After sale service
1. Free guide to install and debugging
2. Free training and consult
3. Guiding how to protect your equipment
4. We will set up clients' document, tracking service, regular inspection, maintenance for life
5. We offers pure perennial spare parts and maintenance engineers will be ready to provide.
Dingbo Cloud on line service will help you to manage your equipment, save cost and improve efficiency.
1.High-strength alloy cast iron engine body, forging crankshaft, and connecting rod employing the cracking technology are adpoted, which ensure high reliability after years of full verification by market.
2.Advanced and mature electronically-control common rail(BOSCH) and high-efficient turbocharged intercooled technologies are adopted, which ensure precise control of fuel-injection quality and sufficient air intake;and the full combustion and less emission of diesel engine under different load conditions are ensured.
3.The internally-cooled oil channel is adopted for piston, which effectively reduced piston temp. and ensures the long service life.
4.Requirements for generator set performance grade G3 is satisfied.
The 175 kVA power range occupies a particularly versatile position in the generator market — large enough to power medium-scale commercial and industrial facilities, yet compact and cost-efficient enough to serve as a standalone standby or prime power unit for individual buildings or process lines.
Commercial Buildings & Hotels
A 175 kVA Yuchai diesel generator set is well-suited as the primary standby power source for a mid-scale hotel (80–150 rooms), office building (3,000–8,000 m²), or retail complex. The unit can maintain power to lighting, elevator systems, HVAC controls, fire safety systems, and POS/IT equipment during grid outages.
Hospitals and Healthcare Facilities
Medical facilities require standby power that starts within 10–15 seconds of mains failure and sustains continuous operation without voltage fluctuation. The YC6A230-D30's electronic governing system and the tight voltage regulation (±1% with Stamford AVR) meet the stability requirements of sensitive medical equipment including imaging systems, ventilators, and surgical lighting.
Telecommunications Infrastructure
Telecom base stations, data aggregation points, and communication relay stations require reliable prime or standby power in locations that may lack grid connection. The 175 kVA output is sufficient to serve a medium-capacity BTS installation with room for load growth.
Industrial and Manufacturing
Production lines, injection moulding machines, CNC equipment, and process heating systems in small-to-medium manufacturing facilities typically require 100–200 kVA of standby capacity. The DB-140GF fits this window precisely, with the engine's strong transient load-acceptance capability accommodating the high inrush currents of motor-driven machinery.
Construction Project Site Power
On construction sites where grid connection is pending or unavailable, the 175 kVA Yuchai generator set provides prime power for site tools, lighting, temporary offices, and welding equipment simultaneously.
Real Estate Development — Temporary Power
Multi-unit residential construction projects require reliable temporary power throughout the build cycle. The open-frame version of the DB-140GF offers the lowest capital cost for this application, with the option to upgrade to a canopy unit for urban sites with noise restrictions.
Agricultural and Irrigation Applications
Pump-driven irrigation systems in agricultural regions with unreliable grid supply use diesel generator sets of this class as prime power for the irrigation season. The YC6A's fuel efficiency and ease of field maintenance are key selection factors in agricultural applications.
Yuchai Power Generation YC6A230-D30 175 Kva Generator Specification
| Diesel Generator Set Data | ||||||
| Manufacturer: | Guangxi Dingbo Generator Set Manufacturing Co.,Ltd Co.,Ltd | |||||
| Set Type: | DB-140GF | |||||
| Prime Output: | 140KW/175KVA | |||||
| Rated Current: | 252(A) | |||||
| Rated Frequency: | 50(Hz) | |||||
| Start-up time: | 5~6(s) | |||||
| Power Factor: | 0.8(Lag) | |||||
| Rated Voltage: | 400/230(V) | |||||
| Standard Features | ||||||
Engine: YUCHAI YC6A230-D30 Radiator 50℃ max Fans are driven by belt, with safety guard 24V charge alternator Dry type air filter, fuel filter, oil filter Alternator: single bearing alternator, IP22-IP23, insulation class H/H Main line circuit breaker Standard control panel Absorber Muffler Factory test report, User manual etc. | ||||||
| Diesel Engine Data | ||||||
| Manufacturer: | YUCHAI | |||||
| Model: | YC6A230-D30 | |||||
| Prime/Standby Power: | 155KW/171KW | |||||
| Rated Speed: | 1500(r/min) | |||||
| Cycle: | 4 stroke | |||||
| Cylinder Arrangement: | 6 in line | |||||
| Displacement: | 7.25L | |||||
| Bore and Stroke: | 108*132(mm) | |||||
| Compression Ratio: | 17.5:1 | |||||
| Governor Type: | Electronic | |||||
| Start battery voltage: | 24V DC | |||||
| Air Intake System | ||||||
| Air Intake System: | Turbocharged and Intercooled | |||||
| Min Intake Restriction: | 100kpa | |||||
| Exhaust System | ||||||
| Exhaust Temperature: | ≤650℃ | |||||
| Max Allowable Back Pressure: | 10kpa | |||||
| Fuel System | ||||||
| Fuel System: | Direct injection | |||||
| 100%( Prime Power) Load: | 39.3L/h | |||||
| 50%( Prime Power) Load: | 27.1L/h | |||||
| Oil System | ||||||
| Total Oil Capacity: | 22L | |||||
| Oil Consumption ratio: | <0.1% | |||||
| Cooling System | ||||||
| Cooling Way: | Water-cooled | |||||
| Total Coolant Capacity: | 36L | |||||
| Thermostat: | 70-8℃ | |||||
| Max Water Temperature: | 102℃ | |||||
| Alternator Data | ||||||
| Manufacturer: | STAMFORD/SIEMENS/MARATHON/ENGGA /LEROY SOMER | |||||
| Excitation Mode: | Brushless and self- exciting | |||||
| Number of phase and Access Act: | 3-phase 4-wire | |||||
| Connecting Type: | “Y” type connecting | |||||
| Alternator Capacity: | 175KVA | |||||
| Alternator Efficiencies: | 95% | |||||
| Overload: | (PRP)110% load can run 1h | |||||
| Protection Level: | IP22-IP23 | |||||
| Insulation Class, Temperature Rise: | H/H | |||||
| Telephone Influence Factor (TIF): | <50 | |||||
| THF: | <2% | |||||
| Voltage Regulation, Steady State: | ≤±1% | |||||
| Altitude: | ≤1000m | |||||
| Genset Electrical Performance | ||||||
| Voltage Regulation: | ≥±5% | |||||
| Voltage Regulation, Stead State: | ≤±1% | |||||
| Sudden Voltage Warp (100% Sudden Reduce): | ≤+25% | |||||
| Sudden Voltage Warp (Sudden Increase): | ≤-20% | |||||
| Voltage Stable Time (100% Sudden Reduce): | ≤6S | |||||
| Voltage Stable Time (Sudden Increase): | ≤6S | |||||
| Frequency Regulation, Stead State: | ≤5% | |||||
| Frequency Waving: | ≤1.5% | |||||
| Sudden Frequency Warp (100% Sudden Reduce): | ≤+12% | |||||
| Sudden Frequency Warp (Sudden Increase): | ≤-10% | |||||
| Frequency Recovery Time(100%Sudden Reduce): | ≤5S | |||||
| Frequency Recovery Time(Sudden Increase): | ≤5S | |||||
| Options | ||||||
| Engine | Alternator | |||||
| Heater | Anti Condensation Heater | |||||
| Battery Charger | Permanent Magnet Generator(PMG) | |||||
| Water Separator | Drop CT(For Paralleling) | |||||
| Daily Fuel Tank | ||||||
| Fuel Level Sensor | ||||||
| Control System | Others | |||||
| Remote Control Panel | Rainproof Type | |||||
| Auto Transfer Switch (ATS) | Soundproof Type | |||||
| Paralleling System | Trailer Type | |||||
| Open Type | ||||||
| Overall Size | Weight | |||||
| 2500*1000*1500(mm) | 1700(kg) | |||||
| Soundproof Type | ||||||
| Overall Size | Weight | |||||
| 3500*1400*1800(mm) | 2600(kg) | |||||
More technical information, please send inquiry to us.
To receive a precise factory quotation for the DB-140GF 175 kVA Yuchai diesel generator set within 24 hours, please provide the following at enquiry stage:
Required information:
Intended use: Standby (ESP) or Prime (PRP) rating
Required frequency: 50Hz or 60Hz
Required voltage: 400V / 415V / 440V / 480V (or custom)
Enclosure: Open frame / Silent canopy / Containerised
Alternator brand preference (Stamford / Leroy Somer / Marathon / ENGGA)
Controller requirement: Standard panel / SmartGen / DSE / ComAp
ATS requirement: Yes / No — supply configuration if yes
Destination port and country
Quantity
Optional but helpful:
Site altitude and ambient temperature (for derating check)
Any special requirements: tropicalisation, emission certification, parallel operation, remote monitoring
Payment terms: T/T 30% deposit, 70% balance before shipment; L/C at sight available for qualified orders.
Lead time: Standard configuration 15–20 working days from deposit confirmation. Stock units may be available for faster delivery — enquire at time of order.
Minimum order: 1 unit. Volume pricing from 3 units.
Q: What is the difference between the prime power (175 kVA) and standby power (192.5 kVA) ratings of the DB-140GF?
Prime Power (PRP) is the rating for unlimited continuous operation at variable load — the correct rating to use if the generator is your main power source or runs for extended periods. Standby Power (ESP) is the maximum output available for up to 200 hours per year in applications where utility grid power is normally present. Using a standby-rated generator as a prime power unit will shorten engine and alternator service life and may void the warranty. If in doubt, consult Dingbo's technical team with your load profile.
Q: Is the YC6A230-D30 engine emissions-compliant for import into my country?
The YC6A230-D30 meets China Non-road Stage III and Euro III equivalent emissions standards. For markets requiring Tier 4 Final (USA EPA) or EU Stage V compliance, we can offer alternative engine configurations — please specify your emissions requirement at enquiry stage.
Q: Can I order the 175 kVA Yuchai generator with a Stamford alternator and Deep Sea controller?
Yes. Alternator brand and controller type are specified independently at order stage. The DB-140GF is assembled to your exact configuration — Stamford alternator with DSE7320 controller, for example, is a standard combination we fulfil regularly.
Q: What warranty does the DB-140GF carry?
12 months or 1,000 operating hours from date of commissioning, whichever occurs first. The Yuchai engine and the alternator (Stamford / Leroy Somer / Marathon) carry their respective OEM warranty terms, which are transferable globally through the OEM's service network.
Q: What is the fuel consumption of the 175 kVA Yuchai generator at 75% load?
At 75% load (105 kW output), the YC6A230-D30 typically consumes approximately 28–30 litres of diesel per hour, depending on ambient conditions and fuel density. Full-load consumption is approximately 32–36 litres per hour. Dingbo's factory test report for each unit includes measured fuel consumption data across the load range.
Q: Can the DB-140GF operate in parallel with another generator?
Yes. Parallel synchronisation is available with the ComAp InteliGen controller or Deep Sea DSE7320/8610 controllers with appropriate synchronisation modules. Specify parallel operation at order stage so the correct controller and output circuit breaker configuration can be supplied.
Q: Do you provide after-sales spare parts support?
Yes. Dingbo stocks common consumable and wear parts for all Yuchai engines and alternators and ships globally by express air freight. For Yuchai engines specifically, parts are also available through Yuchai's own global dealer network — a significant advantage over lesser-known engine brands.
| Genset Model | Genset Power | Engine Model | Engine Power | ||
| Prime | Standby | Prime | Standby | ||
| KW | KW | KW | kW | ||
| DB-33GF | 30 | 33 | YC4DTGO | 36 | 40 |
| DB-33GF | 30 | 33 | YC4D60-D21 | 40 | 44 |
| DB-44GF | 40 | 44 | YC4D60-D21 | 40 | 44 |
| DB-55GF | 50 | 55 | YC4D80-D34 | 53 | 58 |
| DB-60GF | 55 | 61 | YC4D90Z-D20 | 60 | 66 |
| DB-60GF | 55 | 61 | YC4D90-D34 | 60 | 66 |
| DB-70GF | 64 | 70 | YC4D105-D34 | 70 | 77 |
| DB-70GF | 64 | 70 | YC4A100Z-D20 | 70 | 77 |
| DB-77GF | 70 | 77 | YC4D120-D31 | 80 | 88 |
| DB-80GF | 75 | 83 | YC6B135Z-D20 | 90 | 99 |
| DB-88GF | 80 | 88 | YC4D140-D31 | 95 | 105 |
| DB-100GF | 90 | 99 | YC6B155L-D21 | 103 | 113 |
| DB-100GF | 90 | 99 | YC4D155-D31 | 103 | 113 |
| DB-100GF | 90 | 99 | YC6B155L-D21 | 103 | 113 |
| DB-110GF | 100 | 110 | YC4A165-D30 | 110 | 121 |
| DB-120GF | 110 | 121 | YC6B180L-D20 | 120 | 132 |
| DB-120GF | 110 | 121 | YC4A190-D30 | 125 | 138 |
| DB-120GF | 110 | 121 | YC6B180L-D20 | 120 | 132 |
| DB-130GF | 120 | 132 | YC6B205L-D20 | 138 | 152 |
| DB-130GF | 120 | 132 | YC6A205-D30 | 138 | 152 |
| DB-150GF | 140 | 154 | YC6A230-D30 | 155 | 171 |
| DB-160GF | 150 | 165 | YC6A230L-D20 | 155 | 171 |
| DB-160GF | 150 | 165 | YC6A245L-D20 | 165 | 182 |
| DB-160GF | 150 | 165 | YC6A245-D30 | 165 | 182 |
| DB-180GF | 160 | 176 | YC6A275-D30 | 184 | 202 |
| DB-220GF | 200 | 220 | YC6MK350-D30 | 235 | 259 |
| DB-220GF | 200 | 220 | YC6MK350L-D20 | 235 | 259 |
| DB-220GF | 200 | 220 | YC6MK350L-D20 | 235 | 259 |
| DB-280GF | 250 | 275 | YC6MK420L-D20 | 281 | 309 |
| DB-280GF | 250 | 275 | YC6MK420-D30 | 281 | 309 |
| DB-280GF | 250 | 275 | YC6MK420L-D20 | 281 | 309 |
| DB-300GF | 280 | 308 | YC6MK450-D30 | 301 | 331 |
| DB-330GF | 300 | 330 | YC6MJ480L-D20 | 321 | 353 |
| DB-330GF | 300 | 330 | YC6MJ500-D21 | 334 | 367 |
| DB-330GF | 300 | 330 | YC6MJ500-D30 | 335 | 369 |
| DB-330GF | 300 | 330 | YC6K500-D31 | 335 | 369 |
| DB-350GF | 320 | 352 | YC6K520-D30 | 356 | 392 |
| DB-350GF | 320 | 352 | YC6T550L-D21 | 368 | 405 |
| DB-380GF | 350 | 385 | YC6T600L-D22 | 401 | 441 |
| DB-380GF | 350 | 385 | YC6T600L-D22 | 401 | 441 |
| DB-380GF | 350 | 385 | YC6K600-D30 | 401 | 441 |
| DB-440GF | 400 | 440 | YC6T660L-D20 | 441 | 485 |
| DB-440GF | 400 | 440 | YC6T660-D31 | 441 | 485 |
| DB-500GF | 450 | 495 | YC6TD780-D31 | 520 | 572 |
| DB-500GF | 450 | 495 | YC6TD780L-D20 | 520 | 572 |
| DB-550GF | 500 | 550 | YC6TD840-D31 | 561 | 617 |
| DB-550GF | 500 | 550 | YC6TD840L-D20 | 561 | 617 |
| DB-600GF | 550 | 605 | YC6TD900-D31 | 605 | 666 |
| DB-660GF | 600 | 660 | YC6C1020L-D20 | 680 | 748 |
| DB-660GF | 600 | 660 | YC6C1000-D30 | 668 | 735 |
| DB-660GF | 600 | 660 | YC6C1020-D31 | 680 | 748 |
| DB-660GF | 600 | 660 | YC6C1020L-D20 | 680 | 748 |
| DB-720GF | 650 | 715 | YC6C1070-D31 | 715 | 787 |
| DB-720GF | 650 | 715 | YC6C1070L-D20 | 715 | 787 |
| DB-820GF | 750 | 825 | YC6C1220-D31 | 815 | 897 |
| DB-880GF | 800 | 880 | YC6C1320-D31 | 880 | 968 |
| DB-880GF | 800 | 880 | YC12VTD1350-D30 | 900 | 990 |
| DB-1000GF | 900 | 990 | YC6C1520-D31 | 1016 | 1118 |
| DB-1000GF | 900 | 990 | YC12VTD1500-D30 | 1000 | 1100 |
| DB-1100GF | 1000 | 1100 | YC6C1660-D30 | 1110 | 1221 |
| DB-1100GF | 1000 | 1100 | YC121680-D31 | 1120 | 1232 |
| DB-1100GF | 1000 | 1100 | YC12VTD1680-D30 | 1120 | 1232 |
| DB-1200GF | 1100 | 1210 | YC12VTD1830-D30 | 1220 | 1342 |
| DB-1300GF | 1200 | 1320 | YC12VC2070-D31 | 1380 | 1518 |
| DB-1400GF | 1300 | 1430 | YC12VTD2000-D30 | 1345 | 1480 |
| DB-1500GF | 1350 | 1485 | YC12VC2270-D31 | 1520 | 1672 |
| DB-1700GF | 1500 | 1650 | YC12VC2510-D31 | 1680 | 1848 |
| DB-1900GF | 1700 | 1870 | YC12VC2700-D31 | 1805 | 1986 |
| DB-2000GF | 1800 | 1980 | YC16VC3000-D31 | 2005 | 2206 |
| DB-2200GF | 2000 | 2200 | YC16VC3300-D31 | 2205 | 2426 |
| DB-2400GF | 2200 | 2420 | YC16VC3600-D31 | 2405 | 2646 |
| Genset Model | Genset Power | Engine Model | Engine Power | ||
| Prime | Standby | Prime | Standby | ||
| KW | KW | KW | kW | ||
| T2 emission | |||||
| DB-90GF | 90 | 100 | YC6B160Z-D20 | 107 | 118 |
| DB-120GF | 120 | 130 | YC6B205L-D20 | 144 | 159 |
| DB-250GF | 250 | 280 | YC6MK420L-D21 | 294 | 321 |
| DB-30GF | 30 | 33 | YC4D65-D20 | 44 | 48 |
| DB-45GF | 45 | 50 | YC4D80Z-D20 | 55 | 60.5 |
| DB-70GF | 70 | 80 | YC6B130Z-D20 | 88 | 97 |
| DB-120GF | 120 | 130 | YC6B210L-D20 | 140 | 154 |
| DB-144GF | 144 | 160 | YC6A245L-D20 | 165 | 181 |
| DB-200GF | 200 | 220 | YC6MJ360L-D20 | 240 | 264 |
| DB-300GF | 300 | 320 | YC6MJ500L-D22 | 334 | 367 |
| DB-400GF | 400 | 440 | YC6TD660L-D21 | 441 | 485 |
| T3 emission | |||||
| DB-19GF | 19 | 21 | 4D24G3 | 22 | 24.2 |
| DB-21GF | 23.5 | 26 | 4D24G1 | 27 | 29.7 |
| DB-31GF | 28 | 31 | 4D24TG7 | 32 | 35.2 |
| DB-31GF | 31 | 34 | 4D24TG3 | 36 | 39.6 |
| DB-19GF | 19 | 21 | 4D24G3/A | 22 | 24.2 |
| DB-26GF | 23.5 | 26 | 4D24G1/A | 27 | 29.7 |
| DB-35GF | 35 | 38 | 4D24TG4/N | 40 | 44 |
| DB-80GF | 80 | 90 | YC4D140-D33 | 95 | 105 |
| DB-120GF | 120 | 132 | YC4D155-D33 | 103 | 113 |
| DB-100GF | 100 | 132 | YC4D180-D33 | 120 | 132 |
| DB-120GF | 120 | 132 | YC4A205-D32 | 138 | 152 |
| DB-150GF | 150 | 160 | YC6A245-D32 | 165 | 181 |
| DB-160GF | 160 | 180 | YC6A285-D32 | 190 | 209 |
| DB-176GF | 176 | 190 | YC6A305-D32 | 203 | 223 |
| DB-200GF | 200 | 220 | YC6MK360-D30 | 240 | 264 |
| DB-250GF | 250 | 280 | YC6MK420-D31 | 281 | 309 |
| DB-300GF | 300 | 330 | YC6MK500-D32 | 335 | 369 |
| DB-450GF | 450 | 500 | YC6TD780-D32 | 520 | 572 |
| DB-500GF | 500 | 550 | YC6TD840-D32 | 561 | 616 |
| DB-550GF | 550 | 600 | YC6TD940-D32 | 628 | 691 |
| DB-600GF | 600 | 660 | YC6TD1020-D32 | 680 | 748 |
Quicklink
Mob.: +86 134 8102 4441
Tel.: +86 771 5805 269
Fax: +86 771 5805 259
E-mail: dingbo@dieselgeneratortech.com
WhatsApp: +86 134 8102 4441