How to Identify Fault Alarm Signals of Diesel Generators

Nov. 11, 2021

In today's society, standby diesel generators are the key equipment to ensure normal operation, whether in manufacturing, medical care, construction, mining and other industries. Otherwise, when the power grid is powered off or powered off, all your equipment will stop running, affecting the normal operation of relevant businesses. Today, Dingbo Power reminds all customers of the warning signal that the generator is about to fail. In order to ensure the normal supply of the enterprise, we also suggest that you replace the old generator with a new diesel generator before it is scrapped, so as to ensure the stability and reliability of power supply. The following warning signals should be focused on below points.


1. The generator is not started.

If your diesel generator fails to start normally after many tests, it may mean that the service life of the generator is over. However, you should not skip this conclusion. In fact, before purchasing a new generator, some other potential reasons why the generator can not start should be explored. However, if you notice other subsequent signs, you may need to consider them.


How to Identify Fault Alarm Signals of Diesel Generators

2. The generator has been used for too long.

Most standby generators can operate for 1000-10000 hours. As long as the critical value is reached, the generator will be close to the end of its life.


3. Generator maintenance is more and more frequent.

Generator set is a machine. Like all machines, it needs regular maintenance and unscheduled maintenance. But if one problem becomes another and then another, it means that your discoverer begins to split. Buying a new generator now costs more time and money than repairing a faulty system.


4. Carbon monoxide emissions are increasing.

Each standby generator produces different levels of carbon monoxide. However, when the generator begins to emit too much carbon monoxide, its service life is coming to an end. At this time, the use of power generation opportunities does pose a risk to health and safety.


5. Consistency disappeared.

As long as the generator is properly maintained, it can still provide inconsistent performance. If the lights start flashing and the appliance can't get the power it needs, it may mean that your generator is starting to fail. When the transmitter output is normal, the replacement of the generator can help protect electrical appliances and key systems from damage.


6. The fuel is burned by the engine.

Generators that suddenly began to consume more diesel sent signals that their operating efficiency was reduced. This is because the mechanical parts have failed and can no longer operate normally and efficiently.


If you have any questions about diesel generators, please contact Dingbo. The generator expert team and sales team of Dingbo will help you select new diesel generators that can meet the needs of your enterprise or unit.

Follow Us

WeChat

WeChat

Contact Us

Mob.: +86 134 8102 4441

Tel.: +86 771 5805 269

Fax: +86 771 5805 259

E-mail: dingbo@dieselgeneratortech.com

Skype: +86 134 8102 4441

Add.: No.2, Gaohua Road, Zhengxin Science and Technology Park, Nanning, Guangxi, China.

Get in Touch

Enter your email and receive the latest news from us.

Copyright © Guangxi Dingbo Power Equipment Manufacturing Co., Ltd. All Rights Reserved | Sitemap Update cookies preferences | privacy-policy
Contact Us