Handling the Boiling over Phenomenon of the Tank During Operation of Diesel Gensts

Nov. 17, 2026

What is the "Boiling‑over" Phenomenon


When a diesel engine is running, water overflows from the filler neck of the water tank, with steam and bubbles spouting out. This is the "boiling‑over" phenomenon caused by excessively high temperature of the diesel engine coolant.

 

Taboos for Handling

 

1. Do not shut down the unit immediately. Shutdown stops coolant circulation, and heat will accumulate rapidly in the cylinder block, giving rise to secondary accidents such as cylinder scoring and cylinder head deformation.

2. Do not attempt to open the water tank cap, otherwise scalding hot liquid may spurt out and cause scald injuries.

3. Do not pour cold water onto the diesel engine cylinder block or cylinder head. This may cause cracking of the diesel generator set cylinder block due to sudden cooling.

 

Handling the Boiling over Phenomenon of the Water Tank During Operation of Diesel Generators


Core Principles for Emergency Handling of Boiling‑over

 

Strictly follow the emergency‑handling principles: reduce load, maintain circulation, cool down gradually, and prevent scalds.

 

Emergency Handling Procedures

1. Remove the load. The fuel injection quantity will decrease automatically, and the combustion temperature inside cylinders drops rapidly.

2. Allow the generator set to run at idle speed with no load for 5‑10 minutes.

3. Observe the reading change of the water temperature gauge.

4. Open all doors and windows of the equipment room or turn on exhaust fans to lower the ambient temperature.

5. Shut down the engine only after the water temperature drops below 70‑80℃.

6. After the water temperature falls below 50℃ (the upper radiator hose feels not scalding to hand), fully cover the water‑tank cap with thick cotton cloth or gloves. Loosen it slowly by about half a turn to allow steam to vent safely through the gap. Completely unscrew the cap only after confirming no residual pressure exists.

7. Add coolant after the engine is fully cooled down.

8. The unit can be put into loaded operation only after troubleshooting is confirmed complete. Do not place the unit into service if the fault remains unresolved.

9. If boiling‑over occurs together with low engine oil pressure or abnormal noises, shut down the unit immediately to prevent cylinder scoring and shaft seizure.

 

Handling the Boiling over Phenomenon of the Water Tank During Operation of Diesel Generators

 

Preventive Measures


1. Daily inspection: check coolant level, belt tension and radiator cleanliness.

2. Replace coolant periodically to prevent scaling and corrosion.

3. Keep the high‑temperature alarm device intact and functional.

4. Ensure adequate air intake and exhaust for the equipment room; do not block the radiator.

 

Dingbo Power specializes in the supply, technical support, maintenance and after‑sales service of various diesel generator sets. Backed by our experienced technical team, we deliver professional on‑site fault troubleshooting, routine maintenance guidance and spare‑part matching services. Our solutions help you effectively avoid common faults including water‑tank boiling‑over and ensure stable and reliable operation of your generator equipment.

 

Should you have demands for diesel generator sets, spare‑parts procurement or require professional technical consultation, please feel free to contact us at dingbo4@dieselgeneratortech.com or Whatsapp +8618077798658.

 


Follow Us

WeChat

WeChat

Contact Us

Mob.: +86 134 8102 4441

Tel.: +86 771 5805 269

Fax: +86 771 5805 259

E-mail: dingbo@dieselgeneratortech.com

WhatsApp: +86 134 8102 4441

Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China

Get in Touch

Enter your email and receive the latest news from us.

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap Update cookies preferences | privacy-policy
Contact Us