When utility power fails or is interrupted, a diesel generator set serves as a backup power source that starts quickly and supplies power to the connected equipment. To achieve the highest operational safety and service life of the generator set, regular maintenance and servicing are essential. Strict compliance with the relevant maintenance and servicing requirements will ensure the performance of the generator set and, at the same time, avoid damage to the environment.
Checks before Sarting
1.Whether the engine oil and cooling water levels meet the specified requirements.
2.Whether the air intake and exhaust ducts of the generator set are unobstructed.
3.Whether the fuel level in the day tank is sufficient.
4.Whether the starting battery voltage and the starting system are normal.
5.Whether tools, parts or other objects have been left on or around the generator set; they must be cleared away before starting.
6.When the ambient temperature is below 5 °C, the generator set should be preheated before starting.
Checks during Starting and Running
1.Whether the engine oil pressure, engine oil temperature and coolant temperature meet the specified requirements.
2.Whether the readings of all instruments and indicator lamps are normal.
3.Whether the cylinders are working properly and the exhaust is normal.
4.Whether there is severe vibration or abnormal noise while the diesel engine is running.
5.Power may be supplied only after the voltage and frequency (speed) have reached the specified values and the set is running stably.
6.Whether low-frequency oscillation occurs in the system after power is supplied.
Power Supply after Starting
The load must not be powered immediately after start-up. The set must run for 5–8 min until the coolant temperature and the oil temperature reach 60 °C, after which normal power supply may begin. Otherwise, cylinder scoring (piston seizure) and cracks in the cylinder head may easily occur, or the generator may shut down on protection.
Shutdown, Fault Shutdown, Inspection and Records
1.Normal shutdown: when utility power is restored or the test run is completed, disconnect the load first, run at no load for 3–5 min, then shut off the fuel supply and stop the engine.
2.Fault shutdown: in the event of low oil pressure, high coolant temperature, high speed, abnormal voltage or other faults, the set should be shut down automatically or manually.
3.Emergency shutdown: in the event of excessive speed (runaway), a personal injury accident or any other dangerous condition of the equipment, the fuel circuit and the air intake circuit should be cut off immediately to shut down the set.
4.Records: after a fault shutdown or an emergency shutdown, proper inspection and records must be carried out; the generator set must not be restarted until the fault has been eliminated and normal operation restored.
Management of the Diesel Generator Set
1.The diesel generator set must never be started under load; it must be started at no load. Otherwise, cylinder scoring may occur and the generator exciter may be damaged.
2.Engine oils of different grades must not be mixed.
3.Do not open the radiator pressure cap while the set is running under load, to prevent scalding by steam.
4.The battery must be replaced when its capacity has deteriorated to 80 % of the rated capacity.
Noise Reduction and Heat Dissipation in the Generator Room
In practice, many generator rooms that have been treated for noise reduction still present problems. The most common one is that the noise reduction target is met at the expense of ventilation air flow, which results in poor heat dissipation in the room. Especially in hot summer, many such rooms have to keep doors and windows open during operation to ensure ventilation and heat dissipation. Noise reduction and heat dissipation are a pair of sharp contradictions, and the emphasis placed on each of them shifts with the change of seasons. To achieve the desired noise reduction effect, noise leakage must be minimized and doors and windows opened as little as possible; however, the materials used for noise reduction also have a thermal insulation effect, which is unfavourable to heat dissipation. If the room is to dissipate heat adequately, sufficient ventilation air flow must be provided; otherwise, the output power of the diesel engine will be affected and the temperature rise in the room will increase.
Dingbo Power is a professional manufacturer of diesel generator sets. We provide complete power solutions covering genset supply, technical support, maintenance and after‑sales service. Our experienced engineering team can offer on‑site troubleshooting, regular maintenance guidance and spare parts matching to keep your generator running steadily and reliably. Whether you need a new generator set, spare parts, or professional technical advice for your power project, please feel free to contact us at dingbo4@dieselgeneratortech.com or Whatsapp +8618077798658.
Previous None
Next 15 KW Gasoline Inverter Genset Durable Adaptability Stable Reliable Power
Quicklink
Mob.: +86 134 8102 4441
Tel.: +86 771 5805 269
Fax: +86 771 5805 259
E-mail: dingbo@dieselgeneratortech.com
WhatsApp: +86 134 8102 4441
Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China