1) Adjust the oil supply of diesel generator according to different altitude
In the plateau area, the air is thin and the mixture is relatively thicker, resulting in incomplete combustion, which reduces the power of diesel generators and increases fuel consumption. To this end, the oil supply should be appropriately reduced. Generally, the oil supply should be adjusted 100% according to the design at the altitude of 1000m, 6% should be reduced from 1000 to 2000m, 15% should be reduced from 2000 to 3000m, and 22% should be reduced above 3000m.
2) Proper use of diesel generators
It is difficult to start the diesel generator by pressure ignition, so the diesel generator should strictly follow the correct cold start method. The e area below 5℃ can be preheated, and the cold area should be equipped with special preheating equipment to start, or add starting liquid (such as a mixture of ether and aviation gasoline).
After starting, idle for 3-5min, and then raise the generator set to medium speed without shaking. The temperature of the generator set can only be started when it rises to above 60℃.
Do not idle for a long time, so as to increase the heating time of the generator set, but also cause the fuel injector gel and carbon accumulation.
3) Diesel generator load should be selected before the smoke limit
The friction loss of the generator set in low load condition is relatively large, the mechanical efficiency and power are low, so the oil consumption rate is high. As the load increases, the mechanical efficiency increases, and the oil consumption per unit power decreases gradually. The load of the diesel generator must be selected before the smoke limit, and the maximum fuel supply is adjusted between the lowest fuel consumption point and the smoke limit point.
Diesel generator in the heavy load operating condition, such as loading and other circumstances exhaust pipe smoke indicates that the load of the generator set has been too large should be changed into low driving, do not stomp on the accelerator pedal smoke driving causing unnecessary waste of fuel.
4) Maintain the normal working temperature of the generator set
Increase the cooling water temperature of diesel generator The normal outlet water temperature of diesel generator is 65-95 ℃. At present, it is generally below 45℃. Waste of oil, oil can not burn completely. Fuel consumption. Oil viscosity, parts movement friction resistance, high oil consumption.
DINGBO POWER is a manufacturer of diesel generator set, the company was founded in 2017. As a professional manufacturer, DINGBO POWER has focused on high quality genset for many years, covering Cummins, Volvo, Perkins, Deutz, Weichai, Yuchai, SDEC, MTU, Ricardo, Wuxi etc, power capacity range is from 20kw to 3000kw, which includes open type, silent canopy type, container type, mobile trailer type.
What Is Alternator in Diesel Generator?
Mar. 17, 2025
Quicklink
Mob.: +86 134 8102 4441
Tel.: +86 771 5805 269
Fax: +86 771 5805 259
E-mail: dingbo@dieselgeneratortech.com
WhatsApp: +86 134 8102 4441
Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China