In order to ensure the normal operation of the whole building in the case of power failure of the public grid, generators are often purchased as backup power, so as to ensure that the normal work and life of the whole building residents will not be affected by power failure. But if the generator set is used in the process, there is a low load, it needs to attract high attention. So is it dangerous for diesel generators to operate at low load? Have you paid attention to these three signals?
Before we officially introduce the three red flags, we need to know that diesel generators operating at low load are really dangerous. If the generator is operating under load, please take immediate action to stop the power supply, otherwise it will have a serious impact.
The first thing to look for is a signal of poor fuel combustion in the diesel generator set. If the generator set burns badly, soot powder can be seen and the piston can be blocked. If such a signal is seen, it is recommended to temporarily shut down the power supply, examine the cause of poor fuel combustion, and clean up the blocked ash powder before restarting the generator set. It is not recommended to put the generator set back into service until the ash has been cleaned.
Secondly, we should pay attention to the signal of carbon deposition of diesel generator set. In fact, people who often drive know that gasoline combustion will not be sufficient to accumulate carbon. In fact, diesel combustion is not sufficient, there will be carbon deposition. It is recommended to cut off the power supply immediately after seeing carbon accumulation in the generator set. For generating units, carbon deposition is a harmful cycle with very bad effects. If left unchecked, it will cause irreversible damage to the generator set.
The third thing to pay attention to is that the signal is a wisp of white smoke. If the diesel generator set produces a wisp of white smoke in the process of operation, it is likely that the generator set is running at low load. In the process of low load operation of the generator set, the piston ring and cylinder can not expand normally, affecting the airtightness, and white smoke will be produced.
DINGBO POWER is a manufacturer of diesel generator set, the company was founded in 2017. As a professional manufacturer, DINGBO POWER has focused on high quality genset for many years, covering Cummins, Volvo, Perkins, Deutz, Weichai, Yuchai, SDEC, MTU, Ricardo, Wuxi etc, power capacity range is from 20kw to 3000kw, which includes open type, silent canopy type, container type, mobile trailer type. So far, DINGBO POWER genset has been sold to Africa, Southeast Asia, South America, Europe and Middle East.
Contact Us
Mob.: +86 134 8102 4441
Tel.: +86 771 5805 269
Fax: +86 771 5805 259
E-mail: dingbo@dieselgeneratortech.com
Skype: +86 134 8102 4441
Add.: No.2, Gaohua Road, Zhengxin Science and Technology Park, Nanning, Guangxi, China.
What Is Alternator in Diesel Generator?
Mar. 17, 2025
Quicklink
Mob.: +86 134 8102 4441
Tel.: +86 771 5805 269
Fax: +86 771 5805 259
E-mail: dingbo@dieselgeneratortech.com
WhatsApp: +86 134 8102 4441
Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China