Advantages of Parallel Operation of Diesel Generating Sets

Dec. 01, 2021

Nowadays, many facts are proving that the world is increasingly dependent on electricity for work and development. Strengthening the power framework, such as diesel generators, is taking on an undeniable key part. In terms of ensuring continuous power supply. Your decision on the generator mainly depends on the measurement of enhanced power, which is required by your specific application. In many cases, you may only need basic enhanced power supply to ensure the continuous operation of the basic machine or task basic hardware.


Or on the other hand, your generator may at least be able to help all equipment of the enterprise operate normally. In any case, it can usually make your generator fully match your needs. However, the output power limit of standard generator sets available in the market may sometimes greatly exceed your basic preconditions, Or it is related to your greatest needs, which is the problem that parallel diesel generator can solve.


The most direct way to set up the parallel framework is to use diesel generators. The adaptive method to solve the decline of power demand is to have at least two diesel generators. In any case, they can be connected in parallel with the parallel switchgear to achieve maximum output when necessary or sufficient output in different cases.


power generators 800kw


What are the advantages of diesel generating set parallel operation?

Compared with a single large diesel generator set, parallel operation of generator sets is basically more recommended. Nevertheless, due to the cost, space and unpredictability requirements and the limitations of keeping up with abnormal conditions. With the emergence of advanced computerized control technology, it is now proved that the requirements for parallel operation of generator sets are significantly reduced, and parallel operation of generator sets can provide additional power.


(1) Reliability

Compared with the base load provided by a single diesel generator set, the repetition of parallel tasks of multiple diesel generators naturally provides more noteworthy reliability. If a unit is in short supply, the basic burden is to redistribute between different units within the framework on the premise of need. In many cases, the base load that requires the most amazing level of rugged reinforcement power usually represents only a fraction of the general power generated by the frame. The generator sets operate in parallel, which means that the most basic components will have important repeatability to maintain the power supply, whether one of the units is off or not.


(2) Scalability

When measuring generators to coordinate your needs prerequisites, it is often difficult to accurately expand the increments in the heap and make adequate arrangements for additional necessities. If the pile forecast is strong, your potential interest in diesel generators may be higher than usual. Again, without a stack projection, you will not have a reliable backup power supply. Or it may be necessary to switch to expensive generator overhaul, or although another unit is obtained in general.


Through the parallel operation of generator sets, the requirement to consider diversity is low without affecting your budget or the need for expensive units used occasionally. No matter how long you have enough physical space, the generator can provide additional power when needed. Therefore, the repetitive diesel generator can be disconnected from the unit and can be used independently in different locations.


(3) Flexibility

The parallel use of various unit diesel generators provides more outstanding adaptability than using a single high limit estimation diesel generator. Multiple diesel generators operating in parallel should not be clustered together and can be in this situation. In the cycle design, the requirement for a huge impression of a single, larger generator is reduced. Setting up rooftop facilities or small generators in restricted areas is just a few ways you can creatively find ways to fit them. Since these units do not need an overall huge space that must be adjacent, these spaces can be introduced regularly in small offices or where any space is a limiting variable.


(4) Easy support and maintainability

The possibility of diesel generator separation or maintenance in the frame is very small. A single unit can deteriorate and be adjusted without affecting the work of different units. The repetition feature in the parallel architecture provides different layers of insurance and ensures the continuous power supply of the basic circuit.


(5) Cost feasibility and quality performance

Single diesel generators operating in parallel usually have small restrictions. As part of these generators, engines are usually industrial, street or high-capacity engines, with cutting-edge production innovation, so that they have a high level of unswerving quality and minimum unit power aging.


Today's parallel switchgear can also be associated with PCs and the web for remote inspection. If your enterprise is preparing to configure multiple diesel generators for parallel power generation, Dingbo power can provide you with diesel generator sets with high quality, strong power and strong performance.

Follow Us

WeChat

WeChat

Contact Us

Mob.: +86 134 8102 4441

Tel.: +86 771 5805 269

Fax: +86 771 5805 259

E-mail: dingbo@dieselgeneratortech.com

Skype: +86 134 8102 4441

Add.: No.2, Gaohua Road, Zhengxin Science and Technology Park, Nanning, Guangxi, China.

Get in Touch

Enter your email and receive the latest news from us.

Copyright © Guangxi Dingbo Power Equipment Manufacturing Co., Ltd. All Rights Reserved | Sitemap Update cookies preferences | privacy-policy
Contact Us