Overload Test of Power Generating Set

Oct. 29, 2021

Let the generator bear 110%P hours, the voltage, frequency, speed and capacity elements are adjusted to the rated value, mainly to check the operation of each part of the generator, there should be no abnormal noise and abnormal vibration.

1. The principle of evaluation according to law and operation inspection.

2. The filling content includes four tables: Annual inspection:

Environmental impact assessment Emergency generator sets and emergency switchboards should be tested for utility to strictly check whether the power supply is reliable and the integrity of the device; simulate the power failure of the main power station for automatic start-up test.

3. The connotation of safety evaluation. Intermediate inspection: inspection and repair in the same year; renewal inspection.

(1) The follow-up evaluation of the planning environmental impact assessment. The emergency generating set or the conversion mechanism shall be subjected to the load test of the main maximum load in the emergency state.

(2) For emergency generator sets or conversion devices that are normally preventive inspection or minor repairs to disintegration, installation and inspection should be carried out; use the normal load maximum load test under emergency conditions for 1-2 hours.


Power Generating Set


4. The principle of integrity inspection.

(1) If the windings of the emergency generator set or conversion device are disassembled and replaced, the repair and installation process and quality should be inspected, and the corresponding tests should be carried out. Only after qualified and normal installation and operation can the ship be assembled, and the installation quality should be strictly checked. The temperature rise test for the rated power of the generator is generally not less than 4 hours, and the temperature rise should not exceed the temperature rise limit.

(2) If the diesel generator is disassembled and repaired, the load test shall be carried out in accordance with the inspection requirements of the diesel generator.

(3) During the load test, the generator or conversion mechanism should be able to operate stably without abnormal noise, vibration and excessive heat. Check whether the voltage, current, frequency and power indications are normal, and check the ventilation and surface cleanliness. Situation: Measure the thermal insulation resistance after the test, and the allowable value of the thermal insulation resistance after rewinding should not be less than 1MΩ.

(4) Check the operating conditions of the commutator or slip ring. When running under rated load, the commutator spark should not exceed Class 1 and there should be no spark on the slip ring.

(5) When the generator has original severe vibration or when any rotating parts such as the rotor (armature) winding, commutator, steel wire and fan blade are replaced during repair, static and dynamic balance inspections are required (the rated speed is less than 1000 speeds) Of generators only need to be static.

(6) Balance test).

The windings of the generator rotor (armature) should undergo a flying test after being replaced, the speed is 120% of the rated speed, and it lasts for 2 minutes without harmful deformation.

(7) The generator whose winding has been unwound shall be subjected to a withstand voltage test.

Not every diesel generator set can run at overload. Diesel generator sets generally have prime power and standby power. During the operation of the diesel generator set, the general power will fluctuate up and down. The standby power is the power that the diesel generator set can achieve, but it is not the power used for a long time. Therefore, we must understand the power of diesel generator set when we buy the diesel generator set. When the diesel generator set enters overload operation, the diesel generator set with four protections will protect itself and stop power supply, which is not very harmful to the diesel generator set.

The operation of diesel generator set in high load environment will make the internal pocket money of diesel generator set age rapidly, which will seriously affect the use of diesel generator set. And it will produce high temperature and deform the parts. When the bearing capacity of the unit is exceeded, the crankshaft in the diesel engine is broken and the diesel engine is scrapped.

Dingbo power suggests that when purchasing diesel generator set, you must select the diesel generator set with correct power according to your own use situation and do a good job in maintenance, so as to increase the service life of diesel generator set.

Follow Us

WeChat

WeChat

Contact Us

Mob.: +86 134 8102 4441

Tel.: +86 771 5805 269

Fax: +86 771 5805 259

E-mail: dingbo@dieselgeneratortech.com

Skype: +86 134 8102 4441

Add.: No.2, Gaohua Road, Zhengxin Science and Technology Park, Nanning, Guangxi, China.

Get in Touch

Enter your email and receive the latest news from us.

Copyright © Guangxi Dingbo Power Equipment Manufacturing Co., Ltd. All Rights Reserved | Sitemap Update cookies preferences | privacy-policy
Contact Us