Influence of Environment And Temperature to Diesel Generator Set

Nov. 30, 2021

The operation mode of the generator set is various, which directly determines the different working conditions for the normal operation of the diesel generator set is different interference.  This paper mainly explains: normal operation of the working environment temperature for the interference of the generator set.  

Too high or too low ambient temperature may interfere with the normal operation of the lift.  The normal operating temperature of diesel generator set should be in the middle of 7℃~40℃.  Need special attention is, even if the external environment temperature in the normal temperature range, if the machine in the overload operation, and operation time is too long, can cause diesel generating set temperature rise, therefore, we must pay special attention to when operating the running time of your goods, the normal operation after period of time, to let the machine for cooling cooling,  Avoid damage to diesel generator equipment.  

Mobile tractor type generator set  

(1) When the ambient atmospheric pressure drops, the ambient temperature rises and the air humidity increases, the dry gas sucked into the cylinder of the diesel engine may be reduced, and the power of the diesel engine may decrease.  Conversely, the diesel engine's power will increase.  That when the environment temperature is too low current tank cooling water temperature too low, the oil temperature and then decline, viscosity of oil at low temperature is bigger, the liquidity ratio is not so good, not only improve the generator parts damaged, and considering the parts work friction resistance increases, the mechanical power loss increase, the output power of the generator set may be decreased.  

The external environment of the normal operation of the generator set is also very critical, especially in the hot summer and cold winter.  It seems that winter temperature has advantages and disadvantages to the generator set, even so, we should pay special attention to the maintenance and maintenance of the generator set, in the case of normal operation at lower temperatures, we should also pay special attention to the operation of the generator set, early prevention of failure, to ensure the normal operation of safety.  

(2) Heat loss increases, fuel consumption increases when the generator set runs normally at a lower temperature, the cooling water brings a lot of heat to the cylinder, which increases its heat loss;  The mixed gas can not be generated and burned efficiently, and fuel consumption will increase by 8% to 10%.  After dropping fuel into the cylinder, it will clean the oil film on the inner wall of the cylinder and penetrate into the crankcase, improving the wear rate of parts, diluting the oil in the oil pan, improving fuel consumption and reducing power output.  


  What Is the Interference of Ambient Temperature to Diesel Generator Set


(3) working environment temperature is too low, cylinder temperature can be very low, the water vapor in the air cylinder is easy to set on the inner wall of the cylinder, and diesel generator is burned into sulfur dioxide encounter water cooling on the inner wall of the cylinder, might have become a strong corrosive product stick on the inner wall of the cylinder, so the cylinder wall surface may suffer from severe corruption, causing the surface of metal materials institution;  When the cylinder liner and piston ring are honed to each other, the dispersed metal materials on the surface of the decay layer will be quickly damaged and loose, or corrosion spots and pits will occur on the surface of the cylinder liner during normal operation  。

(4) the deterioration of combustion, the ability of the whole equipment is affected by a bit of thermal deformation of the parts because of the ambient temperature is too low and does not splash up to the shape size, and then interfere with the normal operation of the machine, such as the piston and cylinder clearance is too large, the seal is not good;  Valve clearance is too large to be affected by rocker arm impact, and the diesel generator is difficult to start.  In the normal operation of the diesel engine, the high temperature of the reduced gas is the prerequisite to ensure the fuel fire. When the ambient temperature of the cylinder, piston and other parts decreases, the reduction should be reduced to the ambient temperature.  

Dingbo has a wild range of diesel generators:Volvo / Weichai/Shangcai/Ricardo/Perkins and so on,if you need pls call us :008613481024441 or email us :dingbo@dieselgeneratortech.com

Follow Us

WeChat

WeChat

Contact Us

Mob.: +86 134 8102 4441

Tel.: +86 771 5805 269

Fax: +86 771 5805 259

E-mail: dingbo@dieselgeneratortech.com

Skype: +86 134 8102 4441

Add.: No.2, Gaohua Road, Zhengxin Science and Technology Park, Nanning, Guangxi, China.

Get in Touch

Enter your email and receive the latest news from us.

Copyright © Guangxi Dingbo Power Equipment Manufacturing Co., Ltd. All Rights Reserved | Sitemap Update cookies preferences | privacy-policy
Contact Us