Analysis of Several Common Safety Hazards of Diesel Generator Set

Jan. 11, 2022

First think of diesel generating set must first understand what an industry, communications industry, now because of diesel generating sets are now used in the communications industry the back-end load have not reached full load transport, even much lower than male child, belongs to the "big horse-drawn cart" phenomenon, so at ordinary times is not easy to find and handle problems in a timely manner.  In emergency situations, after the mains is shut down, the diesel generator set must immediately provide power to the rear load. Although the communication equipment has backup power sources such as batteries and UPS, they are all short-term power supply equipment, so the diesel generator set becomes the last guarantee for the backup power source of communication.  Once the diesel generator set carrying capacity and the electrical characteristics do not meet the requirements of communication electricity, will not be able to normal power supply, will lead to communication interruption, this kind of accident occurs from time to time, all over the country, we can put the cause of this accident analysis, in order to put forward an effective solution.  

 

According to our long-term investigation and research on backup power supply in the communication industry, the following points need special attention:  

Since there is no special instrument for loading test machine, it is impossible to detect whether the output rated power and load capacity can meet the design requirements after the completion of the project, which directly affects the acceptance of the project;  Although the environmental noise of some units is reduced after the installation of noise reduction equipment, there is a certain impact on the output power of the unit. It is impossible to detect how much output power of the unit is lost. Whether the quality of noise reduction engineering meets the contract requirements according to the original design and how much reasonable power loss of the unit is guaranteed.  

How to prolong the service life of the generator, so that the generator can maximize the energy, the early installation of diesel generator set is very important, the following are the installation precautions:  

 1, the installation site should be well ventilated, the generator end should have enough air inlet, the diesel unit end should have good air outlet.  Air outlet area should be more than 1.5 times the water tank area;  The air inlet is not smooth or does not meet the requirements, the air into the cylinder is less, so it will cause insufficient fuel in the cylinder, produce carbon deposition, affect the carrying capacity of the diesel generator set;  Similarly, the exhaust pipe does not meet the requirements, and the air oxygen content in the machine room is reduced, which will also cause insufficient fuel in the cylinder, produce carbon deposition, and affect the carrying capacity of the diesel generator set.  


 Volvo Genset


2, the installation site should be kept clean around, avoid placing in the vicinity can produce acid, alkaline and other corrosive gases and steam items.  If conditions permit, fire extinguishing devices shall be installed.  

3, in indoor use, must be smoke exhaust pipe outdoor, pipe diameter must be greater than or equal to the muffler smoke pipe diameter, the pipe elbow should not be more than 3, in order to ensure smooth smoke exhaust, and should tilt the pipe down 5-10 degrees, to avoid rainwater injection;  If the exhaust pipe is installed vertically upward, a rain cover must be installed.  In order to increase the output power of diesel generator set, in the case of a cylinder capacity and number of certain, only to force more air into the cylinder to make the fuel burning inside the cylinder, can raise the mean effective pressure, diesel generating sets are currently using the turbocharger, the exhaust of diesel generator set is strict,  Once the exhaust is not smooth or the exhaust gas speed does not meet the requirements, the air entering the cylinder is reduced, which will cause the diesel generator set to decrease its carrying capacity.  

4,When the foundation is made of concrete, the levelness shall be measured with a level during installation so that the unit is fixed on a level basis.  There should be special shock cushion or bottom bolt between the unit and the foundation.   

5, the unit shell must have reliable protection grounding, the need for neutral direct grounding of the generator, it must be neutral grounding by professionals, and equipped with lightning protection device, it is strictly prohibited to use the grounding device of the mains for neutral direct grounding.  

6, The two-way switch between the generator and the mains must be very reliable in order to prevent power transmission.  The connection reliability of the bidirectional switch must be verified by the local power supply department.  

7,The wiring of the starting battery must be firm.  In summary, after the installation of the diesel generator set, it is necessary to carry out acceptance, mainly the load capacity test and electrical characteristics test, whether it can reach the power level of the original bidding requirements or whether it meets the capacity requirements of the original design, so that you can have a clear idea and avoid the occurrence of safety accidents.  


Dingbo has a wild range of diesel generators:Volvo / Weichai/Shangcai/Ricardo/Perkins and so on,if you need pls call us :008613481024441 or email us :dingbo@dieselgeneratortech.com.


Follow Us

WeChat

WeChat

Contact Us

Mob.: +86 134 8102 4441

Tel.: +86 771 5805 269

Fax: +86 771 5805 259

E-mail: dingbo@dieselgeneratortech.com

Skype: +86 134 8102 4441

Add.: No.2, Gaohua Road, Zhengxin Science and Technology Park, Nanning, Guangxi, China.

Get in Touch

Enter your email and receive the latest news from us.

Copyright © Guangxi Dingbo Power Equipment Manufacturing Co., Ltd. All Rights Reserved | Sitemap Update cookies preferences | privacy-policy
Contact Us