Safety Management Of Perkins Diesel Generator Sets

Sep. 18, 2023

Perkins generator sets adhere to its safer, more reliable, cleaner, personalized needs and high reliability professional products to meet users' needs.

 

1.Safety and warnings in the generator set room

 

Perkins diesel generator set must be operated by personnel who are familiar with the equipment structure, principles, and master safety operating procedures.

 

(1) Before using and maintaining the generator set, it is necessary to read and understand Perkins generator set manual and other relevant random materials.

(2) The correct installation of the generator set is a prerequisite for its normal use, and only by using qualified spare parts for maintenance can the generator set achieve good operating conditions and a longer service life.

(3) The generator set must be operated by trained personnel, repairs must be carried out by authorized personnel, and operators and maintenance personnel must understand safety precautions and operation and maintenance procedures.

(4) Only start the generator set when ensuring safety, and do not start it with knowledge of any abnormalities to avoid unexpected situations.

(5) When cleaning, maintaining, or repairing the generator set, it is necessary to first shut down the machine and disconnect the negative switch of the battery or remove the battery connection cable, and place a warning sign in the corresponding position to avoid unexpected situations.


Perkins Diesel Generator


(6) The exhaust gas emitted by the engine is harmful to human health, and all generator sets installed indoors must discharge the exhaust gas outdoors.

(7) During the operation of the generator set, smoke exhaust pipes and silencers will generate high temperatures. When installing and using them, fire-resistant insulation materials should be used and flammable materials should be kept away.

(8) Ensure that there is good and sufficient ventilation and a clean environment in the computer room.

(9) Do not store flammable and explosive objects (liquids) near the engine.

(10) Smoking, sparking, or other ignition behaviors near the battery and fuel are not allowed, as the volatile gas of the fuel and the hydrogen generated during battery charging can cause explosions when encountering sparks or open flames.

(11) The computer room should be equipped with BC and ABC fire extinguishers, and operators and maintenance personnel should be required to know how to use them.

(12) Do not attempt to start the machine when the fan protective cover or other safety protective cover is removed; Do not attempt to reach under or near these protective devices for maintenance when turning on the machine.

(13) Keep palms, arms, long hair, jewelry, and loose clothing away from pulleys, belts, and other rotating parts.

(14) When working in the computer room, it is necessary to wear work clothes, gloves, and hats.

(15) After the generator set is running and the coolant is not completely cooled, do not attempt to unscrew the radiator cover to prevent steam (hot water) from spraying out and injuring people.

(16) Do not ingest or allow skin to come into contact with liquids such as fuel, coolant, lubricants, and electrolytes; Once splashed with these liquids, rinse immediately with plenty of water.

(17) Long term exposure to high noise can be harmful to human hearing. When working around generator sets, it is recommended to wear ear protection equipment.

(18) When connecting power output cables, the generator set must comply with the relevant conditions, specifications, and standards for power distribution, and use qualified power cables for power distribution output.

(19) When welding is required to install the generator set, it is strictly prohibited to ground or ground the generator set (body)! To prevent welding high current from damaging the generator.

 

2.Security Management of Perkins diesel generator

 

(1) Diesel generators must be stored indoors in a designated dry, dark, and ventilated area when not in use. It is strictly prohibited to store the diesel generator in the open air, in direct sunlight, or in areas where it may be soaked by rain.

(2) The oil engine used in the service hall is not allowed to be unused for a long time (30 days), and the fuel in the diesel generator should be fully drained.

(3) In the storage area of diesel generator oil, prevent long-term accumulation of oil and gas in the air, and pay attention to waiting for sufficient air convection, especially when it has dissipated before entering or exiting.

(4) The diesel generator body must be clearly labeled with diesel generator exhaust is toxic; Signs such as Prohibit use in non ventilated environments' and 'Prohibit adding fuel or oil during operation'.

(5) Dry powder fire extinguishers should be equipped in the storage area of the discharge motor. Dry powder fire extinguishers should be used for extinguishing oil fires, and carbon dioxide fire extinguishers should be used for extinguishing equipment.

(6) It is strictly prohibited to stack the diesel generator, oil drum with flammable and explosive materials, cardboard boxes, wooden boxes, foam and other sundries.

(7) It is strictly prohibited to use non-metallic containers such as plastic drums to load fuel.


3. Diesel generator transportation management

 

(1) When handling diesel generators, it is necessary to lift and handle them gently, and it is strictly prohibited to throw, drop, collide, and other rough loading and unloading.

(2) During transportation and handling of diesel generators, no fuel should be stored inside the machine. Fuel can only be injected to generate electricity after reaching the destination.

(3) Due to dry winter weather, in order to prevent the generation of static sparks, before operating diesel generators and oil drums, both hands should first touch well grounded metal objects, such as buried water pipes.

Follow Us

WeChat

WeChat

Contact Us

Mob.: +86 134 8102 4441

Tel.: +86 771 5805 269

Fax: +86 771 5805 259

E-mail: dingbo@dieselgeneratortech.com

Skype: +86 134 8102 4441

Add.: No.2, Gaohua Road, Zhengxin Science and Technology Park, Nanning, Guangxi, China.

Get in Touch

Enter your email and receive the latest news from us.

Copyright © Guangxi Dingbo Power Equipment Manufacturing Co., Ltd. All Rights Reserved | Sitemap Update cookies preferences | privacy-policy
Contact Us